Regulation Decoded
Your Annual
Fire Safety Statement
Just Got Harder
CURRENT AS AT 22 SEPTEMBER 2026
12 MIN READ
BY BUILT SMART SOLUTIONS
SEO/AI under the hood (amended per review actions 2 & R4): exact-match H1 restored per audit 2.1 – the personality line survives as the subhead · URL /services/certification/ per the audit keyword map · meta description: “Principal Certifier Appointment, Construction & Occupation Certificates and Complying Development (CDC) from one specialist, ISO 9001-certified team – approval to occupation.” (adopted from Option 1’s written set) · the “Quick Answer” block is deliberately extractable – it’s the sentence we want ChatGPT/Gemini/AI Overviews to quote · FAQPage + Service schema · 800+ words at full build · division-coded breadcrumb.
ON THIS PAGE
- 01. Where this sits in the reform programme
- 02. Whose obligation this actually is
- 03. What AS 1851-2012 requires, and where it stops
- 04. Why this is harder than swapping contractors
- 05. The practitioner who has to sign
- 06. The annual cycle
- 07. Five failures we see repeatedly
- 08. Penalties, stated properly
- 09. Strata buildings specifically
- 10. What to do before your next statement
- 11. What lands in February 2027
- 12. FAQ
Quick answer
From 13 February 2026, section 81A of the Environmental Planning and Assessment (Development Certification and Fire Safety) Regulation 2021 requires the owner of a building to ensure that maintenance activities for each essential fire safety measure are carried out in accordance with an approved performance solution where one addresses the activity, and otherwise in accordance with AS 1851-2012 where that standard addresses the activity. Building Commission NSW describes the reform as applying to class 1b and class 2 to class 9 buildings.
This does not create new fire safety obligations. It prescribes how existing ones must be met: specific service frequencies, specific test methods, and specific records. Section 81A(2) separately requires the owner to keep the records the standard requires on site for at least seven years.
If your maintenance contract still says “in accordance with manufacturer’s recommendations”, it no longer describes what the law requires, and your accredited practitioner may not be able to sign your next statement.
Where this sits in the reform programme
This is not a new rule dropped on the sector. It is stage three of four, and it was deferred once already.
| Stage | Commenced | What it did |
|---|---|---|
| One | 13 February 2023 | Councils and certifiers able to correct minor errors in fire safety schedules, or replace a missing schedule on request. Builders required to lodge the fire safety certificate with the building compliance declaration for class 2, 3 and 9c buildings. |
| Two | 1 August 2023 | Certifiers required to consult Fire and Rescue NSW on fire safety design proposals that depart from the deemed to satisfy provisions. Councils and certifiers required to use the standard Fire Safety Schedule template. A revised template took effect 28 July 2025. |
| Three | 13 February 2026 | Owners must ensure essential fire safety measures are inspected, tested and serviced in accordance with AS 1851-2012 where the standard addresses the activity, or in accordance with the relevant performance solution. Records kept on site for seven years. Deferred from 13 February 2025. |
| Four | 13 February 2027, or 18 months after a new accreditation scheme is approved, whichever occurs first | Owners must use an accredited person to certify newly installed fire safety measures before issuing a fire safety certificate, and name that person in the certificate. Also deferred from 13 February 2025. |
Whose obligation this actually is
Get this right and everything else follows. Get it wrong and you will under manage a risk that sits squarely with you.
Section 81A imposes the duty on the owner of the building, and on no one else. There is no parallel statutory duty on the servicing contractor under that section. Building Commission NSW confirms that a person does not need to be an Accredited Practitioner (Fire Safety) to carry out AS 1851-2012 work; contractors must hold the appropriate licences and qualifications for the work they do, but their obligation to work to AS 1851-2012 arises from their contract with you and from their licence conditions.
You will read elsewhere that the obligation applies equally to the practitioners doing the maintenance. It does not. The consequence of believing it does is that you assume the risk is shared, and relax. It is not shared. If the servicing is not done to the standard, or the records do not evidence that it was, the person exposed is the owner.
The response is not to worry about it. It is to engage contractors on terms that expressly require AS 1851-2012 compliance and the delivery to you of the records section 81A(2) requires you to hold.
What AS 1851-2012 requires, and where it stops
AS 1851-2012 is the Australian Standard for routine service of fire protection systems and equipment. It is not new. Many well managed buildings have followed it for years. What changed is that it moved from optional to prescribed, and section 81A(3) adopts it as in force from time to time, so a future revision applies without any further change to the Regulation.
For each type of system the standard sets out four things: how often it must be serviced, what the service must involve, what the pass and fail criteria are, and what must be recorded. Routine service runs at monthly, quarterly, six monthly and annual intervals, with five yearly, ten yearly, twenty five yearly and thirty yearly activities for some systems. Those long interval items are the ones that catch buildings out, because nobody in the current management chain was there when the clock started.
Two limits that matter
A performance solution prevails, activity by activity. Where a performance solution approved for building work addresses a maintenance activity, that performance solution governs, not the standard’s default. Note the granularity: the test is applied to each maintenance activity, not to a whole system or a whole building. One building can be partly on a performance solution and partly on AS 1851-2012. This is one reason the fire safety schedule matters so much. It records the standard each measure was designed and installed to.
The standard only applies where it addresses the activity. AS 1851-2012 does not cover everything on a typical schedule. Emergency and exit lighting is the clearest example: it sits under AS/NZS 2293, not AS 1851-2012. Where an activity is not addressed by the standard and not addressed by a performance solution, section 81A does not bite on it at all, and the schedule standard continues to govern. Treat this reform as “AS 1851 where it applies”, not “AS 1851 for everything”.
You do not have to buy the standard to read it
AS 1851-2012 is called up by the Regulation but is not published free the way legislation is. Copies can be purchased from Standards Australia. If you need to consult it rather than retain it, the Standards Australia Reader Room provides free, read only access through NSW public libraries. Your servicing contractor should hold a working copy regardless.
Why this is harder than swapping contractors
The baseline data problem
AS 1851-2012 is built on the assumption that you know what you have and what has been done to it. Many buildings do not. Measures have been added, replaced and modified across two decades and three contractors, and the asset register, where one exists, was inherited rather than verified. Servicing to a standard you cannot map to your assets produces records that do not prove anything.
The baseline data problem
A five yearly or ten yearly activity is only meaningful if you can say when it was last done. Where the records do not exist, the honest position is that the interval starts now, and that is a cost that lands in a single year rather than being spread.
Long interval services have a start date
A five yearly or ten yearly activity is only meaningful if you can say when it was last done. Where the records do not exist, the honest position is that the interval starts now, and that is a cost that lands in a single year rather than being spread.
Records are the deliverable
This is the part most owners underestimate. Section 81A(2) requires the records AS 1851-2012 requires to be kept on the premises for at least seven years and made available to the Commissioner of Fire and Rescue NSW or the council on request. That is a standalone obligation with its own penalty. A contractor who services correctly but hands you nothing has left you non compliant.
Buildings with no schedule at all
Older buildings, particularly pre 1997, may have no fire safety schedule. Section 81 deals with this: the measure must be maintained to a standard no less than that to which it was originally designed and implemented, and the owner can ask the council for a schedule of the measures that were originally installed, which the council must provide as soon as practicable. If that describes your building, that request is the first step, not the servicing contract.
The practitioner who has to sign
The annual fire safety statement is issued by or on behalf of the building owner. It must deal with each essential fire safety measure in the building, and it declares two things.
First, that each measure has been assessed by an accredited practitioner (fire safety) and found capable of performing to at least the standard required by the current fire safety schedule or, for measures not on the schedule, the standard to which they were originally designed and implemented. Second, that the building was inspected and found in a condition that did not disclose grounds for prosecution under the fire safety offence provisions, which cover exit systems and paths of travel.
You choose the practitioner. The practitioner’s accreditation is what is on the line. Where the servicing records do not evidence AS 1851-2012 compliance, a practitioner acting properly cannot make that declaration. That is the mechanism by which this reform reaches you: not through an inspection at your gate, but through a professional who will not sign.
The annual cycle
| Requirement | Position |
|---|---|
| Who is responsible | The building owner. For strata, the owners corporation. A strata manager or agent may coordinate it. The legal obligation does not move. |
| Due date | Within 12 months of the date the previous statement, or the final fire safety certificate, was given, whichever is more recent. |
| Assessment window | Assessment and inspection must be carried out within the three months before the statement is issued. |
| Who assesses | An accredited practitioner (fire safety) with a current accreditation number, chosen by the owner. |
| What it covers | Every essential fire safety measure in the building, plus inspection of exits and paths of travel to exits. |
| Where it goes | The local council, and the Commissioner of Fire and Rescue NSW through the FRNSW online portal. |
| Display | A copy, with the current fire safety schedule, prominently displayed in the building. |
| Extensions | There is no statutory power for a council to extend the due date. See below. |
There is no such thing as an extension
The Regulation contains no power for a council to extend the due date for an annual fire safety statement. Once the twelve month period expires, the offence accrues.
What councils have is enforcement discretion, exercised under their own published policies. Some will defer enforcement where a genuine, unanticipated site event has prevented completion, and will generally refuse where the building has a poor compliance history. Treat any indulgence as a decision not to enforce, not as a lawful extension of time. The distinction becomes very important if something happens in the building while you are relying on it.
Five failures we see repeatedly
1. The schedule no longer describes the building
Measures have been added, removed, upgraded or modified over the years without the fire safety schedule being amended. The statement must deal with each measure in the building against the standard in the current schedule. When those two documents disagree, the practitioner has nothing coherent to certify against.
2. The maintenance contract predates the obligation
Contracts written before the reform commonly specify servicing “in accordance with manufacturer’s recommendations” or an agreed schedule. That language no longer describes the legal requirement. It also gives the contractor no obligation to produce AS 1851-2012 records, which is the part you actually need to hold for seven years.
3. The logbook has gaps
Missed monthly checks. A quarterly service performed late. Records held by a contractor who has since been replaced and never handed over. Each gap is minor. Collectively they are the difference between a defensible service history and an assertion.
4. Exit paths are obstructed on the day
The inspection covers exits and paths of travel. Storage in a fire stair. A wedged fire door. A bike locked against an exit. A car park path blocked by a skip. Among the most common findings, the most avoidable, and the ones most directly connected to whether people get out. The obligation is continuous, not annual.
5. Nobody diarised the date
The due date runs from the previous statement, not from the calendar year, so it drifts. In strata schemes where managing agents change, the date is frequently lost. By the time a council reminder arrives, and not every council sends one, the three month assessment window may already be too tight to arrange.
Penalties, stated properly
Failing to lodge an annual fire safety statement is an offence. Failing to display it is a separate offence. Councils enforce through fire safety orders, penalty infringement notices and, for persistent non compliance, prosecution in the Local Court.
The maxima on the face of the Regulation, expressed in penalty units:
| Obligation | Corporation | Individual |
|---|---|---|
| Failure to maintain essential fire safety measures (s 81) | 600 penalty units | 300 penalty units |
| Failure to inspect, test and service per AS 1851-2012 or the performance solution (s 81A(1)) | 600 penalty units | 300 penalty units |
| Failure to keep and produce the records (s 81A(2)) | 300 penalty units | 150 penalty units |
At the current penalty unit value of $110, 600 units is $66,000, 300 units is $33,000 and 150 units is $16,500. The unit value can change, which is why the Regulation uses units and so do we.
Penalty notice amounts are a separate matter. They are set by individual councils under their own published policies and are not uniform across NSW. Several councils operate an escalating weekly scale for an overdue statement. You will find confident statewide figures circulating. The only reliable figure is the one in your own council’s current schedule.
A more useful frame
The fine is rarely the thing that hurts. The exposures that actually bite are the insurance position if a loss occurs in a building whose measures were not maintained to the prescribed standard, disclosure on sale or refinance, personal exposure for strata committee members, and the scrutiny that service records attract after an incident. A statement is a piece of paper. The record behind it is the asset.
Strata buildings specifically
In a strata scheme the owners corporation is the building owner. The obligation to maintain essential fire safety measures, to have them serviced to the prescribed standard, to hold the records and to lodge the statement all sit with it. A strata manager typically coordinates the process. That arrangement does not transfer the legal responsibility.
The practical problem is access. Several essential fire safety measures are physically located within, or at the boundary of, individual lots: smoke alarms, the fire doors serving unit entries, and sprinkler heads. Whether any given item is lot property or common property depends on the strata plan and the by-laws, and in most schemes fire doors and sprinkler heads remain common property despite their location. What matters practically is that the owners corporation cannot discharge its obligations without getting into lots.
Section 122 of the Strata Schemes Management Act 2015 gives an owners corporation power to enter a lot to carry out work it is required to carry out, on notice. Where a lot owner refuses, an application to NCAT is available. That is a slow path, which is why access should be organised well before the assessment window rather than during it.
Older strata buildings
The most exposed buildings are established schemes with long service histories under multiple contractors and no consolidated asset register. If your building is more than fifteen years old and has changed fire contractors more than once, assume the baseline data needs verifying rather than assuming it is sound. Some older buildings will also face upgrade requirements where measures no longer meet contemporary standards, which is a separate question from maintenance and a considerably larger one.
Not sure your schedule matches your building?
Send us the current fire safety schedule and the last two statements. We will tell you where the schedule and the building have drifted apart, and what has to be resolved before your next statement is due. Fixed fee, in writing.
What to do before your next statement
- Find your due date. Twelve months from the last statement or the final fire safety certificate, whichever is more recent. Not the calendar year.
- Get the current fire safety schedule from council. If there isn’t one, ask the council for a schedule of the measures originally installed.
- Reconcile the schedule against the building. Walk it. This is the step that determines whether the rest of the process has anything to certify against.
- Review the maintenance contract. It should require servicing in accordance with AS 1851-2012 where the standard addresses the activity, or the approved performance solution where one does, and it should require the records to be delivered to you.
- Audit the records. Confirm you hold the service history, on site, and that it goes back seven years or as far as the building allows.
- Book the practitioner early. The assessment must fall within the three months before the statement is issued, which is a narrower window than most owners plan for.
- Clear the exit paths before the inspector arrives, and keep them clear afterwards.
Steps one to three and step seven cost nothing and are not our work. Do them yourself. They will tell you whether you have a problem.
What lands in February 2027
From 13 February 2027, or 18 months after a new accreditation scheme is approved, whichever occurs first, building owners must use an accredited person to certify newly installed fire safety measures before issuing a fire safety certificate, and must include information about that person in the certificate.
The reason this stage was deferred is that a new accreditation scheme has to be developed for the function. Until it commences, owners continue to ensure a properly qualified person carries out the assessments before the owner issues the fire safety certificate for new building work.
Plan for a capacity squeeze
A new accreditation scheme means a new pool of accredited people, built from scratch, against a commencement date. If your project will be seeking a fire safety certificate in 2027, do not assume the practitioner you have used for years will be able to perform the function, and do not assume there will be an abundance of people who can. Ask the question in the first quarter of 2027, not the third.
And then the Building Act 2026
The Building (Approvals and Practitioners) Act 2026 passed both Houses on 4 August 2026 and received assent on 14 August 2026. Almost all of it, including this change, awaits proclamation and is not in force. Under it, fire safety certificates will be issued by the approval authority rather than the building owner.
That is a meaningful shift in accountability. Today the owner signs on the strength of a practitioner’s assessment, which puts the signature with the party least equipped to interrogate it. Moving the issue to a registered, insured party facing substantially increased penalties puts it where the technical judgement is.
It does not change the owner’s ongoing obligations. Annual fire safety statements, maintenance of essential fire safety measures, the records rule and the AS 1851-2012 requirement all remain squarely with the building owner.
Key takeaways
- The duty is the owner’s. Section 81A binds the owner of the building. Contractors’ obligations to work to the standard come from their contract and their licence, not from the Regulation.
- 13 February 2026 is the date, for class 1b and class 2 to 9 buildings, and it was deferred once from 2025.
- AS 1851-2012 applies where it addresses the activity. A performance solution prevails activity by activity, and some measures, including emergency and exit lighting, sit under other standards entirely.
- Records are a standalone obligation. Seven years, on site, available to the Fire Commissioner or the council on request.
- There is no extension. Councils have enforcement discretion, not power to move the date.
- The schedule is the reference point. Where it no longer describes the building, the practitioner has nothing to certify against.
- February 2027 brings an accredited person requirement for certifying newly installed measures, against a scheme still being built.
Frequently asked questions
What is an annual fire safety statement?
A statement issued by or on behalf of a building owner declaring that each essential fire safety measure in the building has been assessed by an accredited practitioner (fire safety) and found capable of performing to at least the standard required by the current fire safety schedule, and that the building was inspected and found in a condition that did not disclose grounds for prosecution under the fire safety offence provisions. It goes to the council and to the Commissioner of Fire and Rescue NSW.
When did AS 1851-2012 become mandatory in NSW?
13 February 2026, under section 81A of the Environmental Planning and Assessment (Development Certification and Fire Safety) Regulation 2021. The stage was deferred by twelve months from 13 February 2025.
Does AS 1851-2012 apply to my building?
Building Commission NSW describes the requirement as applying to class 1b and class 2 to class 9 buildings in NSW. Within those buildings it applies to a maintenance activity only where AS 1851-2012 addresses that activity and an approved performance solution does not. A building with no essential fire safety measures has nothing to service.
Who does the obligation fall on?
The owner of the building. In a strata scheme, the owners corporation. Section 81A does not impose the duty on the servicing contractor. Contractors must hold the appropriate licences and qualifications, but their obligation to work to AS 1851-2012 comes from their contract with you.
When is my annual fire safety statement due?
Within twelve months of the date the previous statement, or the final fire safety certificate, was given, whichever is more recent. It runs from that date, not from the calendar year, so it drifts.
How far before the statement can the assessment be done?
The assessment and inspection must be carried out within the three months before the statement is issued. Anything older does not support the statement.
What are the penalties for a late statement in NSW?
Failing to lodge is an offence, and failing to display the statement is a separate offence. The Regulation sets maxima in penalty units, including 600 units for a corporation and 300 for an individual for failing to maintain measures or to service them to the prescribed standard. Penalty notice amounts are set by each council under its own policy and vary, so check your council’s current schedule rather than a statewide figure.
Can I get an extension on my statement?
No. There is no statutory power for a council to extend the due date. Some councils will exercise enforcement discretion where a genuine unanticipated event has prevented completion, but that is a decision not to enforce, not an extension of time, and the offence still accrues.
How long do I have to keep the service records?
At least seven years, on the premises, available to the Commissioner of Fire and Rescue NSW or the council on request. This is a separate obligation from the servicing itself and carries its own penalty.
Who is responsible in a strata building?
The owners corporation. A strata manager may coordinate the process, but the legal obligation stays with the owners corporation. Where an assessment needs access to a lot, section 122 of the Strata Schemes Management Act 2015 gives a power of entry on notice, and an application to NCAT is available where a lot owner refuses.
My building is old. Do I have to catch up on years of missed servicing?
You have to comply from 13 February 2026 forward. The practical problem is that long interval services, five yearly and beyond, cannot be evidenced as done unless the records exist. Where they do not, the honest position is that the interval starts now. Where there is no fire safety schedule at all, section 81 lets you ask the council for a schedule of the measures originally installed, and that is the place to start.
Do I have to buy AS 1851-2012?
Copies can be purchased from Standards Australia. Free read only access is available through the Standards Australia Reader Room at NSW public libraries if you need to consult it rather than hold it. Your servicing contractor should have a working copy in any event.
What changes in February 2027?
Owners will have to use an accredited person to certify newly installed fire safety measures before issuing a fire safety certificate, and name that person in the certificate. The requirement commences on 13 February 2027 or 18 months after a new accreditation scheme is approved, whichever occurs first.
Primary sources and further reading
- NSW Legislation, Environmental Planning and Assessment (Development Certification and Fire Safety) Regulation 2021, sections 81, 81A, 88, 89 and 92
- Building Commission NSW, reforms to building fire safety regulation
- Building Commission NSW, building fire safety requirements under AS 1851-2012, and responsibilities of building owners
- Building Commission NSW, licensing requirements for building professionals under AS 1851-2012
- Fire and Rescue NSW, building fire safety and statement lodgement
- Strata Schemes Management Act 2015, section 122
Related insights: Why your occupation certificate is late · Construction certificates are being replaced: the Building Act 2026 · When your reports don’t talk to each other, neither does your approval
This article is general information about NSW building fire safety regulation prepared by registered certifiers. It is not legal advice and does not take account of the circumstances of any particular building.
Built Smart Solutions · Get Your Project Approved. Keep Your Building Compliant.